3.2. PICKLING UNITS
The Cell has demonstrated the recovery of saleable ferrous sulphate from discarded pickling effluents.

Salient features of technology
-
Effluents reduced considerably:
- By adoption of Drag-out/Reduction techniques
- Provision of nozzle in front of Rinsing pipe.
- Use of Inhibitors/Foaming agents for fumes reduction.
-
Cost of equipment : Rs.75,000/-
-
Ferrous sulphate recovered: : 2 to 2.5 tonnes/month
-
Sale price : Rs.4000-6000/- per tonne
-
Pay back period : 2 years
-
Use of Ferrous Sulphate : Soil conditioner
Two enterprises have set up CETP for managing pickling waste.